CZone Output Interface (OI) with Connector & Boot / Seal
The Output Interface (OI) provides an intelligent replacement for traditional circuit breaker and fuse panels. It has 6x high power, robust output channels which provide the power supply, control and fusing for a circuit as well as integrating many other built in features such as timers and dimmers. Connection to the unit is simple: a large 6 way plug allows connections to cables of up to 16 mm2 (6AWG) in size, or multiple smaller conductors. No need for specialized crimp terminals and expensive crimp tools to be carried for terminations to CZone, just a blade screwdriver. A protective flexible boot offers protection to the connections from harsh environment conditions.
- 4 levels of backup fusing including manual override (as required by ABYC)
- Multiple channels can be bridged together to offer higher current switching
- Power consumption 12 V: 85 mA (standby 60 mA)
- Dimensions, WxHxD: 7-29/32"x5"x1-3/4" 200x128x45 mm
- Small, non metallic, easy to install case
- 6 x 20 amps circuits
- IPX5 water ingress protection
- Programmable software fuse sizes
OI/MOI Features:
- 6x 20A circuits per module (OI)
- Each circuit channel is programmable to o er circuit protection with settable break currents ranging from 200mA to 20Amps
- Multiple channels can be bridged together to the higher current switching
- Selectable fusing characteristics to cater for various load types ie Slow and fast blow, characteristics found in traditional mechanical fuses and circuit breakers
- LED indication for individual circuit and network status
- Robust, reliable electronic design
- Each FET is rated to 75A
- Isolated ground giving electronics protection from ground loops
- Manual Systems override, In case of mechanical failure to network a mechanical override is provided on the OI for each circuit in the form of an ATC fuse. Remove the fuse and place into the bypass position to bypass the OI control
- 4 levels of fusing
- Mechanical fuse
- Hardware short circuit protection
- Software short circuit protection
- Software over current protection
- IPX5 water ingress protection
- Dimensions: H 128mm (5”) x W200mm (7”29/32) x D 45mm (1”3/4)
- Power consumption: @12V: 85mA (standby 60mA)
- Weights: OI = 659g
- Pulse width modulation (Current Control)
- Dimming control of lighting circuits
- Smooth start e ect for turning lighting on gradually
- Soft start for prolonging the life of halogen bulbs through limiting the shock on the lament by high in rush currents found during normal cold switch on. Can also be used to reduce large inrush currents on motors.
- Timer functionality
- Plug and play confguration
- Inputs Network, NMEA 2000
- 5 – 35V DC
- EMC ratings:
• IEC EN 60945 • IEC EN 61000 • FCC Class B • ISO 7637 - 1 (12V Passenger cars and light commercial vehicles with nominal 12 V supply voltage - Electrical transient conduction along supply lines only) • ISO 7637 - 2 (24V Commercial vehicles with nominal 24 V supply voltage - Electrical transient conduction along supply lines only) • IEC Standards for indirect lighting strikes
|