Victron Lynx Shunt VE.CanThe Lynx Shunt VE.Can is an intelligent 1000A shunt with location for a fuse (not included), the built-in battery monitor accurately monitors the state of charge of your battery. Use a GX device (e.g. Cerbo GX) for reading out the information. Part of the modular Lynx distribution system.
Busbar integrated battery monitoring The Lynx Shunt VE.Can contains a positive and negative busbar, a battery monitor and a fuse holder for the main system fuse. It is part of the Lynx Distribution system. The Lynx Distributor has a power LED. The Lynx Shunt VE.Can can communicate via VE.Can with an GX device. The Lynx Shunt VE.Can ships with two RJ45 VE.Can terminators, these are used when connecting to a GX device. The Lynx Shunt VE.Can is designed to hold a CNN fuse. The fuse needs to be purchased separately. For more info see section Fusing in the Lynx Shunt VE.Can manual.
he Lynx Distribution System The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, battery monitoring and/or Lithium battery management. For more information also see the DC Distribution Systems product page. The Lynx Distribution System consist of the following parts: • Lynx Power In - A positive and negative busbar with 4 connections for batteries or DC equipment. • Lynx Distributor - A positive and negative busbar with 4 fused connections for batteries or DC equipment together with fuse monitoring. • Lynx Shunt VE.Can - A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device. • Lynx Smart BMS - For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor that is driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring. It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal.
Specifications: Supply voltage range
| 9 - 70 Vdc | Supported system voltages
| 12/24/48V
| Reverse polarity protection
| No | Current rating
| 1000Adc continuous | Power consumption
| 60mA @ 12V 33mA @ 24V 20mA @ 48V | Potential free alarm contact
| 3A, 30Vdc, 250Vac | Busbar connection
| M8 | Fuse connection
| M8 | VE.Can
| RJ45 and RJ45 terminator | Power supply connection to Lynx Distributor
| RJ10 (a RJ10 cable ships with each Lynx Distributor) | Temperature sensor
| Screw terminal | Relay
| Screw terminal | Enclosure material
| ABS | Enclosure dimensions (h x w x d)
| 190 x 180 x 80 mm | Unit weight
| 1.4 kg | Busbar material
| Tinned copper | Busbar dimensions (hxw)
| 8 x 30 mm | Operating temperature range
| -40°C to +60° | Storage temperature range
| -40°C to +60° | Humidity
| Max. 95% (non-condensing) | Protection class
| IP22 |
|